Wiring Reference: Difference between revisions
Jump to navigation
Jump to search
| Line 12: | Line 12: | ||
5 1 8 1 | 5 1 8 1 | ||
_____________ ____________ | _____________ ____________ | ||
\ | \ o o o o o / | ........ | | ||
\ | \ o o o o / |___ ____| | | ||
--------- |__| | --------- |__| | ||
9 6 Tab | 9 6 Tab | ||
1 Brown 7 | |||
2 Green 5 | |||
3 Red 4 | |||
4 Black 3 | |||
5 Yellow 6 | |||
6 Orange 2 | |||
7 8 | |||
8 Blue 1 | |||
9 - | |||
</pre> | </pre> | ||
Revision as of 22:00, 30 June 2015
Standard Data Ethernet Cable
Wiring pinout wiki we use T568B
Crossover Data Ethernet Cable
http://www.danpex.com/images/crossover.jpg
Server Serial Port <-> Digi Serial Multiplexer
Use a standard ethernet cable pinout. Refer to other RJ45-to-DB9 adapters for the DB9 pinouts.
DB9F RJ-45
5 1 8 1
_____________ ____________
\ o o o o o / | ........ |
\ o o o o / |___ ____| |
--------- |__|
9 6 Tab
1 Brown 7
2 Green 5
3 Red 4
4 Black 3
5 Yellow 6
6 Orange 2
7 8
8 Blue 1
9 -
Cisco <-> Digi Serial Multiplexer
End A: Digiport (snip orange and w/brown)
w/orange loop w/blue green w/green blue loop brown
End B: Cisco
(Mirror of normal):
brown w/brown green w/blue blue w/green orange w/orange