=== DELL (LSI-based) SAS controllers === Here's what the output looks like when running verify.sh on a LSI-based card: <pre> jail2 /mnt/data2# sh /root/verify.sh Adapter #0 Enclosure Device ID: 32 Slot Number: 0 Device Id: 0 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 140014MB [0x11177328 Sectors] Non Coerced Size: 139502MB [0x11077328 Sectors] Coerced Size: 139392MB [0x11040000 Sectors] Firmware state: Online SAS Address(0): 0x500000e018396142 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: FUJITSU MAX3147RC D207DQ03P7A0DESN Foreign State: None Media Type: Hard Disk Device Device Speed: Unknown Link Speed: Unknown Enclosure Device ID: 32 Slot Number: 1 Device Id: 1 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 140014MB [0x11177328 Sectors] Non Coerced Size: 139502MB [0x11077328 Sectors] Coerced Size: 139392MB [0x11040000 Sectors] Firmware state: Online SAS Address(0): 0x500000e018395db2 SAS Address(1): 0x0 Connected Port Number: 1(path0) Inquiry Data: FUJITSU MAX3147RC D207DQ03P7A0DERV Foreign State: None Media Type: Hard Disk Device Device Speed: Unknown Link Speed: Unknown Enclosure Device ID: 32 Slot Number: 2 Device Id: 2 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 286102MB [0x22ecb25c Sectors] Non Coerced Size: 285590MB [0x22dcb25c Sectors] Coerced Size: 285568MB [0x22dc0000 Sectors] Firmware state: Online SAS Address(0): 0x5000c50006eece89 SAS Address(1): 0x0 Connected Port Number: 2(path0) Inquiry Data: SEAGATE ST3300555SS T2113LM4BFBZ Foreign State: None Media Type: Hard Disk Device Device Speed: Unknown Link Speed: Unknown Enclosure Device ID: 32 Slot Number: 3 Device Id: 3 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 286102MB [0x22ecb25c Sectors] Non Coerced Size: 285590MB [0x22dcb25c Sectors] Coerced Size: 285568MB [0x22dc0000 Sectors] Firmware state: Online SAS Address(0): 0x5000c50006eee035 SAS Address(1): 0x0 Connected Port Number: 3(path0) Inquiry Data: SEAGATE ST3300555SS T2113LM4BGF7 Foreign State: None Media Type: Hard Disk Device Device Speed: Unknown Link Speed: Unknown Enclosure Device ID: 32 Slot Number: 4 Device Id: 4 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 286102MB [0x22ecb25c Sectors] Non Coerced Size: 285590MB [0x22dcb25c Sectors] Coerced Size: 285568MB [0x22dc0000 Sectors] Firmware state: Online SAS Address(0): 0x5000c50004bd7ea5 SAS Address(1): 0x0 Connected Port Number: 4(path0) Inquiry Data: SEAGATE ST3300656SS HS093QP0G8SW Foreign State: None Media Type: Hard Disk Device Device Speed: Unknown Link Speed: Unknown Enclosure Device ID: 32 Slot Number: 5 Device Id: 5 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 286102MB [0x22ecb25c Sectors] Non Coerced Size: 285590MB [0x22dcb25c Sectors] Coerced Size: 285568MB [0x22dc0000 Sectors] Firmware state: Online SAS Address(0): 0x500000e01f1c4112 SAS Address(1): 0x0 Connected Port Number: 5(path0) Inquiry Data: FUJITSU MBA3300RC D306BJ15P9201W06 Foreign State: None Media Type: Hard Disk Device Device Speed: Unknown Link Speed: Unknown Exit Code: 0x00 Adapter 0 -- Virtual Drive Information: Virtual Disk: 0 (Target Id: 0) Name: RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0 Size:139392MB State: Optimal Stripe Size: 64kB Number Of Drives:2 Span Depth:1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default Exit Code: 0x00 Adapter 0 -- Virtual Drive Information: Virtual Disk: 1 (Target Id: 1) Name:MIRROR1 RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0 Size:285568MB State: Optimal Stripe Size: 64kB Number Of Drives:2 Span Depth:1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default Exit Code: 0x00 Adapter 0 -- Virtual Drive Information: Virtual Disk: 2 (Target Id: 2) Name:MIRROR2 RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0 Size:285568MB State: Optimal Stripe Size: 64kB Number Of Drives:2 Span Depth:1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default Exit Code: 0x00 Battery FRU : N/A Battery Warning : Enabled Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 BBU : Present BBU : Yes Cache When BBU Bad : Disabled press enter when ready to run verify </pre> Before pressing enter, here's what we're looking for: <pre> Enclosure Device ID: 32 Slot Number: 0 Device Id: 0 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 140014MB [0x11177328 Sectors] Non Coerced Size: 139502MB [0x11077328 Sectors] Coerced Size: 139392MB [0x11040000 Sectors] Firmware state: Online SAS Address(0): 0x500000e018396142 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: FUJITSU MAX3147RC D207DQ03P7A0DESN Foreign State: None Media Type: Hard Disk Device Device Speed: Unknown Link Speed: Unknown </pre> This is the output shown for each physical drive in the system. We're looking to confirm it's Firmware state is ''Online'', and Media Error Count, Other Error Count, and Predictive Failure Count are all zero (or near zero). <pre> Adapter 0 -- Virtual Drive Information: Virtual Disk: 1 (Target Id: 1) Name:MIRROR1 RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0 Size:285568MB State: Optimal Stripe Size: 64kB Number Of Drives:2 Span Depth:1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default </pre> This is the output for each logical drive. We're looking for State ''Optimal''. Also confirm <tt>Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU</tt> <pre> Exit Code: 0x00 Battery FRU : N/A Battery Warning : Enabled Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 BBU : Present BBU : Yes Cache When BBU Bad : Disabled </pre> Confirm that the battery is present and error-free. If all that checks out, you're ready to proceed with the verify. After pressing enter, the verify is started and here's what you see: <pre> Start Check Consistency on Virtual Drive 0 (target id: 0) Success. Exit Code: 0x00 Start Check Consistency on Virtual Drive 1 (target id: 1) Success. Exit Code: 0x00 Start Check Consistency on Virtual Drive 2 (target id: 2) Success. Exit Code: 0x00 Check Consistency Progress of Virtual Drives... Virtual Drive # Percent Complete Time Elps 0 °°°°°°°°°°°°°°°°°°°°°°°00 %°°°°°°°°°°°°°°°°°°°°°°° 00:00:03 1 °°°°°°°°°°°°°°°°°°°°°°°00 %°°°°°°°°°°°°°°°°°°°°°°° 00:00:02 2 °°°°°°°°°°°°°°°°°°°°°°°00 %°°°°°°°°°°°°°°°°°°°°°°° 00:00:01 Press <ESC> key to quit... </pre> The progress for each drive is displayed until all drives have completed the verify. We just want to make sure that each drive goes to completion. No followup is needed...though there probably is a log or history where we can get more info. You will notice that jail7 does not run a verify- that's on purpose. The last time we tried this it crashed the system. So, this must be run from the BIOS (take the system offline for a couple hours). See [[RAIC_CLI#LSI|LSI RAID CLI Reference]] for more details on how to use the CLI
Summary:
Please note that all contributions to JCWiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
JCWiki:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Navigation menu
Personal tools
Not logged in
Talk
Contributions
Create account
Log in
Namespaces
Page
Discussion
English
Views
Read
Edit
View history
More
Search
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Tools
What links here
Related changes
Special pages
Page information